Clinician assessing a patient's knee
All Ongoing Research
Ongoing Research · Observation stage

A one-stage, needle-delivered surgical technique study

MSK DoctorsMSK Doctors

NanoACi 100

The treatment phase of NanoACi 100 is complete and the series is now in its observation stage. Professor Paul Lee reports encouraging early findings, with a four-point reduction in pain on the 0–10 visual analogue scale (VAS) at six-week follow-up. Analysis and follow-up are ongoing.

Part of the MSK injection therapies observational cohort study · REC 26/SW/0096 · IRAS 375544.

100

Treatments complete

Observation

Current stage

6 weeks

Pain follow-up

Autologous micrograftsCollagen scaffoldPRP signalling

The Clinical Imperative

Can cartilage treatment become simpler without losing scientific rigour?

Articular cartilage has limited intrinsic healing capacity. Established autologous chondrocyte implantation pathways can involve arthroscopic harvest, laboratory expansion and a later implantation procedure. NanoACi is designed as a one-stage surgical alternative; NanoACi 100 assesses clinical outcomes following treatment.

Established pathway

Traditional cultured-cell ACI

  • Arthroscopic cartilage harvest
  • Cell culture and laboratory expansion
  • Later implantation procedure
  • Longer, multi-stage treatment pathway
Technique under study

NanoACi

  • Small auricular cartilage harvest
  • Point-of-care mechanical preparation
  • No cell culture or enzyme digestion
  • Needle delivery during one surgical session

Research question

Is the NanoACi technique safe, reproducible and associated with meaningful improvement in pain, function and imaging measures?

The Surgical Technique

One session. Three autologous components.

NanoACi is being studied as a tissue-harvesting, preparation and reimplantation procedure — not simply as an injection. Under local anaesthetic, small cartilage and perichondrial samples are harvested from the auricular concha. The tissue is mechanically prepared at the point of care into micrografts, combined with an in-situ-forming collagen scaffold and platelet-rich plasma (PRP), then implanted by ultrasound-guided needle delivery.

Protocol principle: autologous, mechanically prepared, non-arthroscopic and completed without laboratory cell expansion.

01

Harvest

Auricular cartilage and perichondrium

02

Prepare

Point-of-care mechanical micrografts

03

Combine

Collagen scaffold and autologous PRP

04

Implant

Ultrasound-guided needle delivery

Study Design

Clinical outcomes in the NanoACi 100 series.

The treatment phase of NanoACi 100 is complete and the series is now in its observation stage. Professor Paul Lee reports encouraging early findings, with a four-point reduction in pain on the 0–10 visual analogue scale (VAS) at six-week follow-up. Analysis and follow-up are ongoing. Its purpose is to characterise delivery of the technique, establish an early safety profile and measure clinical and functional change over time.

100

Treatments complete

1

Standardised technique

6

Assessment points

24m

Planned observation

A

Population

Adults with symptomatic knee cartilage disease or osteoarthritis selected through whole-joint clinical assessment.

B

Primary evaluation

Change in Motion Age from baseline to 12 months, alongside systematic procedural and safety reporting.

C

Secondary evaluation

VAS pain, OKS, patient experience, individual movement biomarkers, MRI findings and further intervention.

Outcome Framework

Measuring what changes — and what matters.

The evaluation combines patient-reported experience, objective movement analysis, safety surveillance and structural imaging. NanoACi 100 analysis and follow-up are ongoing.

01

Motion Age

Markerless movement analysis will quantify functional change, including sit-to-stand, squat and related movement biomarkers.

02

Pain & patient experience

VAS pain, Oxford Knee Score (OKS), global improvement and satisfaction will describe the patient-reported response.

03

Safety

Complications, inflammatory reaction, infection, donor-site events, unplanned admission and further intervention will be recorded.

04

MRI

Planned imaging review will assess cartilage thickness and repair morphology at defined follow-up points.

Markerless motion analysis capturing functional movement

Functional Biomarker · Motion Age

Motion Age turns movement into an understandable functional measure.

Beyond questionnaires: markerless video analysis examines how a person moves and compares that pattern with age-related movement benchmarks.

For NanoACi 100, Motion Age will provide an objective complement to pain scores and patient-reported outcomes, helping the study detect whether movement quality changes after the procedure.

Sit-to-standSquatMovement biomarkers

Planned Follow-Up

From baseline to two years.

  1. 0

    Baseline

    Clinical, patient-reported, Motion Age and imaging assessment

  2. 6w

    Early review

    Recovery, safety and rehabilitation progress

  3. 3m

    Initial response

    Pain, function and adverse events

  4. 6m

    Functional review

    Patient outcomes and Motion Age

  5. 12m

    Primary analysis

    Full outcome set, Motion Age and MRI

  6. 24m

    Durability

    Longer-term clinical and imaging follow-up

Study overview · Observation stage

NanoACi 100

Prospective evaluation of a needle-delivered, one-stage autologous chondrogenic surgical technique for knee cartilage disease.

01

Background

Cartilage has limited healing capacity, while established autologous chondrocyte implantation can require tissue harvest, cell culture and a later implantation procedure. NanoACi is a minimally invasive, surgeon-led technique combining auricular cartilage micrografts, a collagen scaffold and platelet-rich plasma during one treatment session.

02

Methods

NanoACi 100 examines clinical outcomes following NanoACi treatment in adults with symptomatic knee cartilage disease or osteoarthritis. Following whole-joint assessment, auricular cartilage and perichondrium will be mechanically prepared at the point of care, combined with collagen scaffold and PRP, and implanted under ultrasound guidance. Assessments are planned at baseline, 6 weeks, 3, 6, 12 and 24 months.

03

Observation stage

The study will characterise procedural safety and reproducibility and examine change in Motion Age, VAS pain, OKS, patient experience, movement biomarkers and MRI features. Further treatment and progression to knee arthroplasty will also be recorded. The treatment phase of NanoACi 100 is complete and the series is now in its observation stage. Professor Paul Lee reports encouraging early findings, with a four-point reduction in pain on the 0–10 visual analogue scale (VAS) at six-week follow-up. Analysis and follow-up are ongoing.

04

Conclusion

With the treatment phase complete, NanoACi 100 now follows every patient through the planned observation points. The early clinical update describes pain at six weeks; continued follow-up will assess function, imaging and the course of recovery.

The Road Ahead

Evidence built in deliberate stages.

Now

Technique evaluation

Treatment phase complete. The consecutive series is now being observed for delivery, safety and clinical signal.

Next

External validation

Replicate findings across surgeons, settings and clearly defined patient groups.

Then

Comparative assessment

Evaluate NanoACi against appropriate established treatments in a controlled design.

Final study registration, eligibility criteria and analysis plan will follow completion of research governance and protocol approvals.

Funding and affiliations

Affiliations: Affiliations as stated in the publication.

Privacy & Cookies Policy